14. EXPANSION FUNCTION
10. Address 0916, 1016, 1716 (=DA5 to 0)
DD15
01 10
DD8DD7
DD0
Bit symbol
Bit name
SEKI0
Data slicer control bit 1
SEKI1
Function
RW
SEKI1
0
0
1
1
SEKI0
0
1
0
1
N
5 (Note1)
4 (Note2)
6 (Note3)
8 (Note4)
N-times the digital value after SEKI7.6.
SEKI2
Data slicer control bit 2
SEKI3
SEKI4
Data slicer control bit 3
SEKI5
SEKI6
Data slicer control bit 4
SEKI7
Data slicer control bit 5
Nothing is assigned.
SISLVL0
Slice level control bit
SISLVL1
BIFON
Slice level measurement
period selection bit
Data format selection bit
Reserved bit
SEKI3 SEKI2
N
0
0
4
0
1
3
1
0
1
1
1
No differentiation
It differentiates from the digitized data
in front of N/8 cycles (clock run-in cycle)
to the digital value after SEKI0 and 1.
SEKI5
0
0
1
1
SEKI4
0
1
0
1
N
4
3
1
No differentiation
It differentiates from the digitized data
in after N/8 cycles (clock run-in cycle)
to the digital value after SEKI3 and 2.
SEKI6
0
1
Leveling existence of the following
A-D convert value
Average for four clocks
It doesn't level
The differentiation by SEKI2, 3,
0 SEKI4, and 5 is differentiated by
one time the value.
1
The differentiation by SEKI2, 3,
SEKI4, and 5 is differentiated by
twice the value.
0 The clock line average level is used
The slice level selection bit
1 (0C16,1316, 1A16, and house number
SLS7?0) is used.
0 2 cycles of Clock run-in
1 4 cycles of Clock run-in
0 Non Return Zero
1 Bi-phase type
Must set to "0."
Reserved bits
Must set to "1."
Reserved bit
Must set to "0."
Note 1. When selecting 5 times with SEKI0, 1 and twice with SEKI7, select "none" for any one
of SEKI2, 3 or SEKI4, 5.
Note 2. When selecting 8 times for SEKI0, 1, select "none" for both SEKI2, 3 and SEKI4, 5.
Note 3. When selecting 6 times for SEKI0, 1 and twice for SEKI7, select "none" for any one of
SEKI2, 3 or SEKI4, 5.
Note 4. When selecting "none" for both SEKI2, 3 and SEKI4, 5, do not select 4 times, and
select 8 times for SEKI0, 1.
Rev.2.10 Oct 25, 2006 Page 209 of 326
REJ03B0152-0210