14. EXPANSION FUNCTION
41. Address 3616 (=DA5 to 0)
DD15
DD8DD7
DD0
Bit symbol
VINT0
VINT1
VINT2
VINT3
Bit name
Function
RW
SLICEON interruption control test bit
0000 : Interrupt disabled (Note 3)
1011 : Interrupt enabled
Others : Do not set up
When the period of data acquisition
expires, the interrupt occurs by setting
these bits to 1011.
Set up the TB5IC register (Note 4)
when use by “Interrupt enabled.”
INTRMT0
INTRMT1
Remote control interruption
control bit (Note 1)
INTRMT2
0000 : Interrupt disabled (Note 3)
1010 : Interrupt enabled
Others : Do not set up
Set up the TB4IC register (Note 4)
when use by “Interrupt enabled.”
INTRMT3
HINT0
HINT1
HINT2
HINT interruption control test
bit (Note 2)
0000 : Interrupt disabled (Note 3)
1001 : Interrupt enabled
Others : Do not set up
Set up the TB3IC register (Note 4)
when use by “Interrupt enabled.”
HINT3
SECINT0
SECINT1
Clock timer interruption
control bit
SECINT2
0000 : Interrupt disabled (Note 3)
1000 : Interrupt enabled (Note 5)
Others : Do not set up
Set up the TB2IC register (Note 4)
when use by “Interrupt enabled.”
SECINT3
Notes 1. Refer to 15.6 Expansion Register Construction Composition.
Notes 2. Refer to the function of HINT_LINEn (Address 3516.)
Notes 3. Set these bits to 0000 when use the interrupt of Timer B2, Timer B3, Timer B4, or Timer B5.
Notes 4. Refer to Figure 6.3 Interrupt Control Registers.
Notes 5. When the second counter (Address 3916) is changed, an interrupt is generated every 1 second.
Notes 6. Please do not change data after setting initial data to address 3616 corresponding interrupt
control bit VINTi, INTRMTi, HINTi, and SECINTi (i = 0 to 3) when you use the SLICEON, remote