M306H7MG-XXXFP Datasheet, PDF (233/329 Pages) Renesas Technology Corp – SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER with DATA ACQUISITION CONTROLLER
M306H7MG-XXXFP/MC-XXXFP/FGFP
14. EXPANSION FUNCTION
48. Address 3D16 (=DA5 to 0) (Note 1)
DD15
DD8DD7
DD0
Bit symbol
Bit name
RMT_TML(0) Carrier L period setting bit
RMT_TML(1)
RMT_TML(2)
Function
Carrier's L period is set.
7
RMT_TML = Σ 2n · RMT_TML(n)
n=0
RMT_TML(3)
RMT_TML(4)
RMT_TML(5)
RMT_TML(6)
RMT_TML(7)
RMT_TMH(0) Carrier H period setting bit
RMT_TMH(1)
RMT_TMH(2)
Carrier's H period is set.
7
RMT_TMH = Σ 2n · RMT_TMH(n)
n=0
RMT_TMH(3)
RMT_TMH(4)
RMT_TMH(5)
RMT_TMH(6)
RMT_TMH(7)
Note 1. Refer to 14.6 "(6) Remote control transmission function."
RW
49. Address 3E16 (=DA5 to 0) (Note 1)
DD15
0
DD8DD7
0
DD0
Bit symbol
RMTTXINT(0)
RMTTXINT(1)
RMTTXINT(2)
Bit name
Function
RW
Remote control transmission 0000: Interrupt prohibition (Note 2)
interrupt control
0001: Interrupt permission
(Note 1, Note 4)
Additionally: Setting prohibition
Please set INT2IC register when using
it by "Interrupt permission."
RMTTXINT(3)
Reserved bit
Must set to "0."
Nothing is assigned.
P84 output signal selection
IROUT_SLICEON bit 2 (Note 3)
0: Normal setting (When use P84 I/O
port or INT2 interrupt.)
1: Remote control transmission pulse
output
Reserved bit
Must set to "0."
Notes 1. Refer to 14.6 "(6) Remote control transmission function."
Notes 2. Set and use 00002 when use INT2 interrupt.
Notes 3. Set "1" to bit b4 of port P8 direction register when use the remote control transmission
function.
Notes 4. Please do not change data after setting the initialization data to remote control
transmission interrupt control bit RMTTXINT(i) (i = 0 to 3) when you use the remote control
transmission interrupt.
Rev.2.10 Oct 25, 2006 Page 233 of 326