SH7108 Datasheet, PDF (412/560 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer | |||
|
◁ |
Section 13 Motor Management Timer (MMT)
TPDR
TCNT
2Td
H'0000
PCIO pin
(toggle output)
Figure 13.7 Example of Toggle Output Waveform Synchronized with PWM Cycle
(13) Settings for A/D Conversion Start Requests
Requests to start A/D conversion can be set up to be issued when TCNT matches TPDR or 2Td.
When the start requests are set up for issue when TCNT matches TPDR, A/D conversion will start
at the center of the PWM pulse (the peak value of the TCNT counter). When the start requests are
set up for issue when TCNT matches 2Td, A/D conversion will start on the edge of the PWM
pulse (the minimum value of the TCNT counter).
Requests to start A/D conversion is enabled by setting the TTGE bit in the timer control register
(TCNR) to 1.
Table 13.3 shows the relationship between A/D conversion start timing and operating mode.
Table 13.3 Relationship between A/D Conversion Start Timing and Operating Mode
Operating Mode
A/D Conversion Start Timing
Operating mode 1 (transfer at peak)
A/D conversion start at trough
Operating mode 2 (transfer at trough)
A/D conversion start at peak
Operating mode 3 (transfer at peak and trough) A/D conversion start at peak and trough
13.4.2 Output Protection Functions
Operating mode output has the following protection functions:
⢠Halting MMT output by external signal
The six-phase PWM output pins can be placed in the high-impedance state automatically by
inputting a specified external signal. There are three external signal input pins. For details, see
section 13.8, Port Output Enable (POE).
Rev.1.00 Sep. 18, 2008 Page 378 of 522
REJ09B0069-0100
|
▷ |