Section 8 Multifunction Timer Pulse Unit (MTU)
(6) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in Reset-Synchronous PWM Mode
Figure 8.89 shows an explanatory diagram of the case where an error occurs in normal mode and
operation is restarted in reset-synchronous PWM mode after re-setting.
MTU module
output
TIOC3A
1
2
3
RESET TMDR TOER
(normal) (1)
4
TIOR
(1 init
0 out)
5
PFC
(MTU)
6
TSTR
(1)
7
8
9
10
Match Error PFC TSTR
occurs (PORT) (0)
11
12
13
TIOR TIOR TOER
(0 init (disabled) (0)
0 out)
14
15
16
17
TOCR TMDR TOER PFC
(CPWM) (1) (MTU)
18
TSTR
(1)
TIOC3B
TIOC3D
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 8.89 Error Occurrence in Normal Mode, Recovery in Reset-Synchronous PWM
Mode
1 to 13 are the same as in figure 8.88.
14. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
15. Set reset-synchronous PWM.
16. Enable channel 3 and 4 output with TOER.
17. Set MTU output with the PFC.
18. Operation is restarted by TSTR.
Rev.1.00 Sep. 18, 2008 Page 240 of 522