English
Language : 

SH7108 Datasheet, PDF (279/560 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
Section 8 Multifunction Timer Pulse Unit (MTU)
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronous PWM Mode
Figure 8.95 shows an explanatory diagram of the case where an error occurs in PWM mode 1 and
operation is restarted in reset-synchronous PWM mode after re-setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TMDR TOER TIOR
(PWM1) (1) (1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
Match
8
9
Error PFC
occurs (PORT)
10
11
12
13
14
TSTR TMDR TIOR TIOR TOER
(0) (normal) (0 init (disabled) (0)
0 out)
15
16
17
TOCR TMDR TOER
(RPWM) (1)
18
PFC
(MTU)
19
TSTR
(1)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
• Not initialized (TIOC3D)
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 8.95 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronous PWM Mode
1 to 14 are the same as in figure 8.90.
15. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronous PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU output with the PFC.
19. Operation is restarted by TSTR.
Rev.1.00 Sep. 18, 2008 Page 245 of 522
REJ09B0069-0100