Section 8 Multifunction Timer Pulse Unit (MTU)
(22) Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in PWM Mode 1
Figure 8.105 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in PWM mode 1 after re-setting.
MTU module
output
TIOC3A
1
2
3
4
RESET TOCR TMDR TOER
(CPWM) (1)
5
6
PFC TSTR
(MTU) (1)
7
8
9
10 11
12
Match Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
• Not initialized (TIOC3D)
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 8.105 Error Occurrence in Complementary PWM Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 8.104.
11. Set PWM mode 1. (MTU output goes low.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Rev.1.00 Sep. 18, 2008 Page 253 of 522