Section 10 Serial Communication Interface (SCI)
Table 10.9 shows the states of the SSR status flags and receive data handling when a receive error
is detected. If a receive error is detected, the RDRF flag retains its state before receiving data.
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 10.9 shows a sample flowchart
for serial data reception.
Table 10.9 SSR Status Flags and Receive Data Handling
SSR Status Flag
RDRF* OER FER PER Receive Data
Receive Error Type
1
1
0
0
Lost
Overrun error
0
0
1
0
Transferred to RDR Framing error
0
0
0
1
Transferred to RDR Parity error
1
1
1
0
Lost
Overrun error + framing error
1
1
0
1
Lost
Overrun error + parity error
0
0
1
1
Transferred to RDR Framing error + parity error
1
1
1
1
Lost
Overrun error + framing error +
parity error
Note: * The RDRF flag retains its state before data reception.
Rev.1.00 Sep. 18, 2008 Page 309 of 522
REJ09B0069-0100