English
Language : 

SH7108 Datasheet, PDF (290/560 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
Section 8 Multifunction Timer Pulse Unit (MTU)
(25) Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Reset-Synchronous PWM Mode
Figure 8.108 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in reset-synchronous PWM mode.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TMDR TOER TOCR TMDR TOER PFC TSTR
(CPWM) (1) (MTU) (1)
occurs (PORT) (0) (normal) (0)
(RPWM) (1) (MTU) (1)
MTU module
output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
Hi-Z
PE9
Hi-Z
PE11
Hi-Z
Figure 8.108 Error Occurrence in Complementary PWM Mode,
Recovery in Reset-Synchronous PWM Mode
1 to 10 are the same as in figure 8.104.
11. Set normal mode. (MTU output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the reset-synchronous PWM mode output level and cyclic output enabling/disabling
with TOCR.
14. Set reset-synchronous PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU output with the PFC.
17. Operation is restarted by TSTR.
Rev.1.00 Sep. 18, 2008 Page 256 of 522
REJ09B0069-0100