SDA 6000
14
Electrical Characteristics
Electrical Characteristics
14.1
Absolute Maximum Ratings
Note: The maximum ratings may not be exceeded under any circumstances, not even
momentarily and individually, as permanent damage to the IC will result.
Table 14-1
Parameter
Ambient Temperature
TA = 0 °C … + 70 °C
Symbol Limit Values Unit
min. max.
Supply voltage 3.3 V
Supply voltage 2.5 V
Analog supply voltage
Storage temperature
Electrostatic discharge
VDD33 1-7
VDD25 1-2
VDDA 1-4
Tstg
–
–
4.0 V
–
3.0 V
–
3.0 V
– 20 125 °C
2000 –
V
Test Condition
–
–
–
–
100 pF, 1.5 kΩ HBM
14.2
Operating Range
Table 14-2 Operating Range
Parameter
Symbol
Ambient temperature
Supply voltage 3.3 V
Supply voltage 2.5 V
Analog supply voltage
Total Power
Consumption
TA
VDD33 1-7
VDD25 1-2
VDDA 1-4
Ptotal
Limit Values
min.
max.
0
70
3.1
3.6
2.25
2.75
2.25
2.75
–
1.5
Unit Test Condition
°C –
V–
V–
V–
W–
Note: In the operating range, the functions given in the circuit description are fulfilled.