English
Language : 

SDA6000 Datasheet, PDF (248/380 Pages) Infineon Technologies AG – Teletext Decoder with Embedded 16-bit Controller
SSC0EN = 1: Operating Mode
SSCCON
SDA 6000
Peripherals
Reset Value: 0000H
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
SSC0 SSC0 - SSC0 SSC0 SSC0 SSC0 SSC0 -
-
-
-
EN MS
BSY BE PE RE TE
rw rw
r rw rw rw rw
SSC0BC
rw
Bit
SSC0BC
SSC0TE
SSC0RE
SSC0PE
SSC0BE
SSC0BSY
SSC0MS
SSC0EN
Function
SSC0 Bit Count Field
Shift counter is updated with every shifted bit. Do not write to!!!
SSC0 Transmit Error Flag
1: Transfer starts with the slave’s transmit buffer not being updated
SSC0 Receive Error Flag
1: Reception completed before the receive buffer was read
SSC0 Phase Error Flag
1: Received data changes around sampling clock edge
SSC0 Baud Rate Error Flag
1: More than factor 2 or 0.5 between Slave’s actual and
expected baud rate
SSC0 Busy Flag
Set while a transfer is in progress. Do not write to!!!
SSC0 Master Select Bit
0: Slave Mode. Operate on shift clock received via SCLK.
1: Master Mode. Generate shift clock and output it via SCLK.
SSC0 Enable Bit = ‘1’
Transmission and reception enabled. Access to status flags and M/S
control.
Note: The target of an access to SSCCON (control bits or flags) is determined by the
state of SSC0EN prior to the access, i.e. writing C057H to SSC0CON in
programming mode (SSC0EN = ‘0’) will initialize the SSC (SSC0EN was ‘0’) and
then switch it on (SSC0EN = ‘1’).
When writing to SSCCON, make sure that zeros are input to reserved locations.
The SSC0 baud rate timer reload register SSCBR contains the 16-bit reload value for
the baud rate timer.
Users Manual
7 - 97
2000-06-15