10.7.12 Offset of Transferred Memory Area (TOR)
This instruction defines the offset value for rectangle memory transfers.
TOR
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
0
1
1
0 GO
D_OFFSET(10..0)
-
-
-
-
-
S_OFFSET(10..0)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit
GO
S_OFFSET
(10 … 0)
D_OFFSET
(10 … 0)
Function
Must be set to ‘1’ if GA is to start memory transfer after executing this
GA-instruction. Otherwise this bit must be set to ‘0’.
Source offset value for non linear transfer
For more information about S_OFFSET refer to Chapter 10.5.2.
Destination offset value for non linear transfer
For more information about D_OFFSET refer to Chapter 10.5.2.