SDA 6000
System Control & Configuration
The new password is defined with command 3 and stored in the according 8-bit field in
the SCUSLS register.
The SCUSLC register is defined as follows
SCUSLC
Reset Value: 0000H
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
COMMAND
rw
Bit
Command
Function
Code of Command to be Executed
Command 0: âAAAAHâ
Command 1: â5554Hâ
Command 2: â96 & inverse passwordâ
Command 3: â000bâ & new level & â000bâ & new password
Command 4: â8EHâ & inverse password (Command 4 unlocks protected
registers for one write access if current security level is in
low protected mode.)
The security level status register SCUSLS is a read only register which shows the
current password, the actual security level and the state of the switching state machine.
The SCUSLS is defined as follows:
Users Manual
6-9