M16C/80 Group
32. Standard serial I/O mode
Block Erase Command
This command erases the data in the specified block. Execute the block erase command as explained
here following.
(1) Transfer the “2016” command code with the 1st byte.
(2) Transfer addresses A8 to A15 and A16 to A23 with the 2nd and 3rd bytes respectively.
(3) Transfer the verify command code “D016” with the 4th byte. With the verify command code, the
erase operation will start for the specified block in the flash memory. Write the highest address of
the specified block for addresses A16 to A23.
When block erasing ends, the RTS1 (BUSY) signal changes from the “H” to the “L” level. After block
erase ends, the result of the block erase operation can be known by reading the status register. For
more information, see the section on the status register.
Each block can be erase-protected with the lock bit. For more information, see the section on the data
protection function.
CLK1
RxD1
(M16C reception data)
TxD1
(M16C transmit data)
RTS1(BUSY)
2016
A8 to A16 to
A15
A23
D016
Figure 32.5 Timing for block erasing
Rev.1.00 Aug. 02, 2005 Page 300 of 329
REJ09B0187-0100