English
Language : 

MC68HC08AZ60A Datasheet, PDF (244/480 Pages) Motorola, Inc – Microcontrollers
Serial Communications Interface (SCI)
RPF — Reception in Progress Flag Bit
This read-only bit is set when the receiver detects a logic 0 during the
RT1 time period of the start bit search. RPF does not generate an
interrupt request. RPF is reset after the receiver detects false start bits
(usually from noise or a baud rate mismatch), or when the receiver
detects an idle character. Polling RPF before disabling the SCI
module or entering stop mode can show whether a reception is in
progress.
1 = Reception in progress
0 = No reception in progress
16.9.6 SCI Data Register
The SCI data register is the buffer between the internal data bus and the
receive and transmit shift registers. Reset has no effect on data in the
SCI data register.
Address: $0018
Bit 7
6
5
4
3
2
1
Bit 0
Read: R7
R6
R5
R4
R3
R2
R1
R0
Write: T7
T6
T5
T4
T3
T2
T1
T0
Reset:
Unaffected by Reset
Figure 16-17. SCI Data Register (SCDR)
R7/T7:R0/T0 — Receive/Transmit Data Bits
Reading address $0018 accesses the read-only received data bits,
R7:R0. Writing to address $0018 writes the data to be transmitted,
T7:T0. Reset has no effect on the SCI data register.
NOTE: Do not use read-modify-write instructions on the SCI data register.
Advance Information
244
Serial Communications Interface (SCI)
MC68HC08AZ60A — Rev 0.0
MOTOROLA