English
Language : 

W90P710_05 Datasheet, PDF (450/526 Pages) Winbond – 16/32-bit ARM microcontroller
W90P710
Smart Card Host Time-out Initial Register 0 (SCHI_TOIR 0)
REGISTER
SCHI_TOIR0_0
SCHI_TOIR0_1
ADDRESS
0xFFF8_502C
0xFFF8_582C
R/W
R/W
R/W
DESCRIPTION
8 bit Time out initial Register 0
8 bit Time out initial Register 1
RESET VALUE
0x0000_0000
0x0000_0000
31
30
23
22
15
14
7
6
BITS
[31:8]
RESERVED
[7:0]
TOIR0
29
28
27
26
25
24
RESERVED
21
20
19
18
17
16
RESERVED
13
12
11
10
9
8
RESERVED
5
4
3
2
1
0
TOIR0[7:0]
DESCRIPTIONS
-
8 bit Time Out Initial Register 0
The value to load in register TOIR 0 is the number of ETU to count.
The time-out counters may only be used when a card is active with
a running clock. This is 8 bit time-out initial register used to initial
loading value when every start counting.
Smart Card Host Time-out Initial Register 1 (SCHI_TOIR 1)
REGISTER
SCHI_TOIR1_0
SCHI_TOIR1_1
ADDRESS
0xFFF8_5030
0xFFF8_5830
R/W
R/W
R/W
DESCRIPTION
16 bit Time out initial Register 0
16 bit Time out initial Register 1
RESET VALUE
0x0000_0000
0x0000_0000
- 450 -