Host Controller Frame Number Register
REGISTER
HcFmNumber
ADDRESS R/W
DESCRIPTION
0xFFF0_503C R Host Controller Frame Number Register
RESET
VALUE
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
FRMN
7
6
5
4
3
2
1
0
FRMN
BITS
[31:16]
[15:0]
Reserved
FRMN
DESCRIPTION
Reserved. Read/Write 0's
FrameNumber
This 16-bit incrementing counter field is incremented coincident with the
loading of FrameRemaining. The count rolls over from ‘000Fh’ to ‘0h.’
Host Controller Periodic Start Register
REGISTER
HcPeriodicStart
ADDRESS R/W
DESCRIPTION
0xFFF0_5040 R/W Host Controller Periodic Start Register
RESET
VALUE
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
PERST
7
6
5
4
3
2
1
0
PERST
- 187 -
Publication Release Date: January 17, 2005
Revision A.2