English
Language : 

MC68HC08AZ16 Datasheet, PDF (484/527 Pages) Motorola, Inc – HCMOS Microcontroller Unit
TIMA Channel
Registers
Appendix B: TIMA-6
I/O Registers
CHxMAX — Channel x Maximum Duty Cycle Bit
When the TOVx bit is at logic 0, setting the CHxMAX bit forces the
duty cycle of buffered and unbuffered PWM signals to 100%. As
Figure 8 shows, the CHxMAX bit takes effect in the cycle after it is set
or cleared. The output stays at the 100% duty cycle level until the
cycle after CHxMAX is cleared.
OVERFLOW
OVERFLOW
PERIOD
PTEx/TCHx
OVERFLOW
OVERFLOW
OVERFLOW
CHxMAX
OUTPUT
COMPARE
OUTPUT
COMPARE
OUTPUT
COMPARE
OUTPUT
COMPARE
Figure 8. CHxMAX Latency
These read/write registers contain the captured TIMA counter value of
the input capture function or the output compare value of the output
compare function. The state of the TIMA channel registers after reset is
unknown.
In input capture mode (MSxB–MSxA = 0:0), reading the high byte of the
TIMA channel x registers (TCHxH) inhibits input captures until the low
byte (TCHxL) is read.
In output compare mode (MSxB–MSxA ≠ 0:0), writing to the high byte of
the TIMA channel x registers (TCHxH) inhibits output compares and the
CHxF bit until the low byte (TCHxL) is written.
27-tima6
MOTOROLA
Appendix B: TIMA-6
MC68HC08AZ32
483