Enhanced Serial Communications Interface (ESCI) Module
ARUN— Arbiter Counter Running Flag
This read-only bit indicates the arbiter counter is running. Reset clears ARUN.
1 = Arbiter counter running
0 = Arbiter counter stopped
AROVFL— Arbiter Counter Overflow Bit
This read-only bit indicates an arbiter counter overflow. Clear AROVFL by
writing any value to SCIACTL. Writing logic 0s to AM1 and AM0 resets the
counter keeps it in this idle state. Reset clears AROVFL.
1 = Arbiter counter overflow has occurred
0 = No arbiter counter overflow has occurred
ARD8— Arbiter Counter MSB
This read-only bit is the MSB of the 9-bit arbiter counter. Clear ARD8 by writing
any value to SCIACTL. Reset clears ARD8.
14.9.2 ESCI Arbiter Data Register
Address: $000B
Bit 7
Read: ARD7
Write:
Reset: 0
6
ARD6
5
ARD5
0
0
= Unimplemented
4
ARD4
0
3
ARD3
0
2
ARD2
0
1
ARD1
0
Figure 14-20. ESCI Arbiter Data Register (SCIADAT)
Bit 0
ARD0
0
ARD7–ARD0 — Arbiter Least Significant Counter Bits
These read-only bits are the eight LSBs of the 9-bit arbiter counter. Clear
ARD7–ARD0 by writing any value to SCIACTL. Writing logic 0s to AM1 and AM0
permanently resets the counter and keeps it in this idle state. Reset clears
ARD7–ARD0.
14.9.3 Bit Time Measurement
Two bit time measurement modes, described here, are available according to the
state of ACLK.
1. ACLK = 0 — The counter is clocked with one half of the bus clock. The
counter is started when a falling edge on the RxD pin is detected. The
counter will be stopped on the next falling edge. ARUN is set while the
counter is running, AFIN is set on the second falling edge on RxD (for
instance, the counter is stopped). This mode is used to recover the received
baud rate. See Figure 14-21.
2. ACLK = 1 — The counter is clocked with one half of the ESCI input clock
generated by the ESCI prescaler. The counter is started when a logic 0 is
detected on RxD (see Figure 14-22). A logic 0 on RxD on enabling the bit
time measurement with ACLK = 1 leads to immediate start of the counter
(see Figure 14-23). The counter will be stopped on the next rising edge of
RxD. This mode is used to measure the length of a received break.