English
Language : 

MC68HC908GR16 Datasheet, PDF (170/310 Pages) Motorola, Inc – Microcontrollers
Freescale Semiconductor, Inc.
Enhanced Serial Communications Interface (ESCI) Module
NOTE:
Table 14-2. Start Bit Verification
RT3, RT5, and RT7 Samples
000
001
010
011
100
101
110
111
Start Bit Verification
Yes
Yes
Yes
No
Yes
No
No
No
Noise Flag
0
1
1
0
1
0
0
0
If start bit verification is not successful, the RT clock is reset and a new search for
a start bit begins.
To determine the value of a data bit and to detect noise, recovery logic takes
samples at RT8, RT9, and RT10. Table 14-3 summarizes the results of the data
bit samples.
Table 14-3. Data Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Data Bit Determination
0
0
0
1
0
1
1
1
Noise Flag
0
1
1
1
1
1
1
0
The RT8, RT9, and RT10 samples do not affect start bit verification. If any or all of
the RT8, RT9, and RT10 start bit samples are logic 1s following a successful start
bit verification, the noise flag (NF) is set and the receiver assumes that the bit is a
start bit.
To verify a stop bit and to detect noise, recovery logic takes samples at RT8, RT9,
and RT10. Table 14-4 summarizes the results of the stop bit samples.
Table 14-4. Stop Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Framing Error Flag
1
1
1
0
1
0
0
0
Noise Flag
0
1
1
1
1
1
1
0
Data Sheet
170
MC68HC908GR16 — Rev. 1.0
Enhanced Serial Communications Interface (ESCI) Module
For More Information On This Product,
Go to: www.freescale.com
MOTOROLA