English
Language : 

MC68HC908GR16 Datasheet, PDF (182/310 Pages) Motorola, Inc – Microcontrollers
Freescale Semiconductor, Inc.
Enhanced Serial Communications Interface (ESCI) Module
TC — Transmission Complete Bit
This read-only bit is set when the SCTE bit is set, and no data, preamble, or
break character is being transmitted. TC generates an ESCI transmitter CPU
interrupt request if the TCIE bit in SCC2 is also set. TC is cleared automatically
when data, preamble, or break is queued and ready to be sent. There may be
up to 1.5 transmitter clocks of latency between queueing data, preamble, and
break and the transmission actually starting. Reset sets the TC bit.
1 = No transmission in progress
0 = Transmission in progress
SCRF — ESCI Receiver Full Bit
This clearable, read-only bit is set when the data in the receive shift register
transfers to the ESCI data register. SCRF can generate an ESCI receiver CPU
interrupt request. When the SCRIE bit in SCC2 is set the SCRF generates a
CPU interrupt request. In normal operation, clear the SCRF bit by reading SCS1
with SCRF set and then reading the SCDR. Reset clears SCRF.
1 = Received data available in SCDR
0 = Data not available in SCDR
IDLE — Receiver Idle Bit
This clearable, read-only bit is set when 10 or 11 consecutive logic 1s appear
on the receiver input. IDLE generates an ESCI receiver CPU interrupt request
if the ILIE bit in SCC2 is also set. Clear the IDLE bit by reading SCS1 with IDLE
set and then reading the SCDR. After the receiver is enabled, it must receive a
valid character that sets the SCRF bit before an idle condition can set the IDLE
bit. Also, after the IDLE bit has been cleared, a valid character must again set
the SCRF bit before an idle condition can set the IDLE bit. Reset clears the
IDLE bit.
1 = Receiver input idle
0 = Receiver input active (or idle since the IDLE bit was cleared)
OR — Receiver Overrun Bit
This clearable, read-only bit is set when software fails to read the SCDR before
the receive shift register receives the next character. The OR bit generates an
ESCI error CPU interrupt request if the ORIE bit in SCC3 is also set. The data
in the shift register is lost, but the data already in the SCDR is not affected. Clear
the OR bit by reading SCS1 with OR set and then reading the SCDR. Reset
clears the OR bit.
1 = Receive shift register full and SCRF = 1
0 = No receiver overrun
Software latency may allow an overrun to occur between reads of SCS1 and
SCDR in the flag-clearing sequence. Figure 14-14 shows the normal
flag-clearing sequence and an example of an overrun caused by a delayed
flag-clearing sequence. The delayed read of SCDR does not clear the OR bit
because OR was not set when SCS1 was read. Byte 2 caused the overrun and
is lost. The next flag-clearing sequence reads byte 3 in the SCDR instead of
byte 2.
Data Sheet
182
MC68HC908GR16 — Rev. 1.0
Enhanced Serial Communications Interface (ESCI) Module
For More Information On This Product,
Go to: www.freescale.com
MOTOROLA