English
Language : 

XC3S100E Datasheet, PDF (114/193 Pages) Xilinx, Inc – DC and Switching Characteristics
R
DC and Switching Characteristics
Table 12: Recommended Operating Conditions for the DLL
Speed Grade
-5
-4
Symbol
Description
Min
Max
Min
Max
Units
Input Frequency Ranges
FCLKIN CLKIN_FREQ_DLL
Frequency for the CLKIN input
5
326
5(2)
280
MHz
Notes:
1. DLL specifications apply when any of the DLL outputs (CLK0, CLK90, CLK180, CLK270, CLK2X, CLK2X180, or CLKDV) are in use.
2. Use of the DFS permits lower FCLKIN frequencies. See Table 14.
Table 13: Switching Characteristics for the DLL
Symbol
Output Frequency Ranges
CLKOUT_FREQ_1X
CLKOUT_FREQ_2X
Description
Speed Grade
-5
-4
Min Max Min Max
Units
Frequency for the CLK0 and CLK180 outputs
Frequency for the CLK90 and CLK270 outputs
Frequency for the CLK2X and CLK2X180
outputs
5 326 5 280
5 165 5 165
10 400 10 330
MHz
MHz
MHz
Notes:
1. The numbers in this table are based on the operating conditions set forth in Table 4 and Table 12.
2. DLL specifications apply when any of the DLL outputs (CLK0, CLK90, CLK180, CLK270, CLK2X, CLK2X180, or CLKDV) are in use.
DS312-3 (v1.0) March 1, 2005
www.xilinx.com
11
Advance Product Specification