English
Language : 

XC3S100E Datasheet, PDF (105/193 Pages) Xilinx, Inc – DC and Switching Characteristics
DC and Switching Characteristics
R
Table 2: Supply Voltage Thresholds for Power-On Reset
Symbol
Description
Min
Max
Units
VCCINTT
VCCAUXT
VCCO2T
Threshold for the VCCINT supply
Threshold for the VCCAUX supply
Threshold for the VCCO Bank 2 supply
0.4
1.0
V
0.8
2.0
V
0.4
1.0
V
Notes:
1. VCCINT, VCCAUX, and VCCO supplies may be applied in any order.
2. To ensure successful power-on, VCCINT, VCCO Bank 2, and VCCAUX supplies must rise through their respective threshold-voltage ranges with
no dips at any point.
Table 3: Power Voltage Levels Necessary for Preserving RAM Contents
Symbol
Description
VDRINT
VDRAUX
VDRO
VCCINT level required to retain RAM data
VCCAUX level required to retain RAM data
VCCO level required to retain RAM data
Notes:
1. RAM contents include configuration data.
Min
Units
1.0
V
2.0
V
1.0
V
Table 4: General Recommended Operating Conditions
Symbol
Description
Min
Nom
Max
Units
TJ
Junction temperature
Commercial
Industrial
0
-
85
°C
–40
-
100
°C
VCCINT
VCCO (1)
VCCAUX (2)
Internal supply voltage
Output driver supply voltage
Auxiliary supply voltage
1.140
1.200
1.260
V
1.140
-
3.450
V
2.375
2.500
2.625
V
Notes:
1. The VCCO range given here spans the lowest and highest operating voltages of all supported I/O standards. The recommended VCCO range
specific to each of the single-ended I/O standards is given in Table 7, and that specific to the differential standards is given in Table 9.
2. Only during DCM operation, it is recommended that the rate of change of VCCAUX not exceed 10 mV/ms.
2
www.xilinx.com
DS312-3 (v1.0) March 1, 2005
Advance Product Specification