CHAPTER 5 CLOCK GENERATORS
5.5 Operation of CPU Clock Generator
A clock (fCPU) is supplied to the CPU from the system clock (fX) oscillated by one of the following three types of
oscillators.
• High-speed internal oscillator:
• Crystal/ceramic oscillator:
• External clock input circuit:
Internally oscillates a clock of 8 MHz (TYP.).
Oscillates a clock of 2 to 10 MHz.
Supplies a clock of 2 to 10 MHz to X1 pin.
The system clock oscillator is selected by the option byte. For details of the option byte, refer to CHAPTER 18
OPTION BYTE.
(1) High-speed internal oscillator
When the high-speed internal oscillation is selected by the option byte, the following is possible.
• Shortening of start time
If the high-speed internal oscillator is selected as the oscillator, the CPU can be started without having to wait
for the oscillation stabilization time of the system clock. Therefore, the start time can be shortened.
• Improvement of expandability
If the high-speed internal oscillator is selected as the oscillator, the X1 and X2 pins can be used as I/O port
pins. For details, refer to CHAPTER 4 PORT FUNCTIONS.
Figures 5-8 and 5-9 show the timing chart and status transition diagram of the default start by the high-speed
internal oscillation.
Remark When the high-speed internal oscillation is used, the clock accuracy is ±5%.
Figure 5-8. Timing Chart of Default Start by High-Speed Internal Oscillation
(a)
VDD
RESET H
Internal reset
System clock
CPU clock
(b)
High-speed internal oscillation clock
PCC = 02H, PPCC = 02H
Option byte is read.
System clock is selected.
(Operation stopsNote)
Note Operation stop time is 277 μs (MIN.), 544 μs (TYP.), and 1.075 ms (MAX.).
User’s Manual U17446EJ5V0UD
81