Chapter 10 Serial Communications Interface (S12SCIV2) Block Description
The transmitting device can address messages to selected receivers by including addressing information
in the initial frame or frames of each message.
The WAKE bit in SCI control register 1 (SCICR1) determines how the SCI is brought out of the standby
state to process an incoming message. The WAKE bit enables either idle line wakeup or address mark
wakeup.
10.4.4.6.1 Idle Input Line Wakeup (WAKE = 0)
In this wakeup method, an idle condition on the Rx Input signal clears the RWU bit and wakes up the SCI.
The initial frame or frames of every message contain addressing information. All receivers evaluate the
addressing information, and receivers for which the message is addressed process the frames that follow.
Any receiver for which a message is not addressed can set its RWU bit and return to the standby state. The
RWU bit remains set and the receiver remains on standby until another idle character appears on the Rx
Input signal.
Idle line wakeup requires that messages be separated by at least one idle character and that no message
contains idle characters.
The idle character that wakes a receiver does not set the receiver idle bit, IDLE, or the receive data register
full flag, RDRF.
The idle line type bit, ILT, determines whether the receiver begins counting logic 1s as idle character bits
after the start bit or after the stop bit. ILT is in SCI control register 1 (SCICR1).
10.4.4.6.2 Address Mark Wakeup (WAKE = 1)
In this wakeup method, a logic 1 in the most significant bit (msb) position of a frame clears the RWU bit
and wakes up the SCI. The logic 1 in the msb position marks a frame as an address frame that contains
addressing information. All receivers evaluate the addressing information, and the receivers for which the
message is addressed process the frames that follow.Any receiver for which a message is not addressed can
set its RWU bit and return to the standby state. The RWU bit remains set and the receiver remains on
standby until another address frame appears on the Rx Input signal.
The logic 1 msb of an address frame clears the receiver’s RWU bit before the stop bit is received and sets
the RDRF flag.
Address mark wakeup allows messages to contain idle characters but requires that the msb be reserved for
use in address frames.{sci_wake}
NOTE
With the WAKE bit clear, setting the RWU bit after the Rx Input signal has
been idle can cause the receiver to wake up immediately.