XRT72L13 Datasheet, PDF (98/370 Pages) Exar Corporation – M13 MULTIPLEXER/CLEAR CHANNEL DS3 FRAMER IC | |||
|
◁ |
XRT72L13 MULTIPLEXER/FRAMER IC
REV. 1.0.6
2.3.2.6 Block Interrupt Enable Register
BLOCK INTERRUPT ENABLE REGISTER (ADDRESS = 0X04)
áç
PRELIMINARY
BIT 7
Rx DS3
Interrupt
Enable
R/W
0
BIT 6
Not Used
BIT 5
Not Used
R/O
R/O
0
0
BIT 4
M13
Interrupt
Enable
R/W
0
BIT 3
Not Used
BIT 2
Not Used
R/O
R/O
0
0
BIT 1
Tx DS3
Interrupt
Enable]
R/W
0
BIT 0
One
Second
Interrupt
Enable]
R/W
0
Bit 7 - Rx DS3 Interrupt Enable
This âRead/Writeâ bit-field permits the user to enable
or disable all âReceive DS3 Framerâ related interrupts
(within the XRT72L13) at the âBlock Levelâ.
Setting this bit-field to â0â disables all âReceive DS3
Framerâ related interrupts within the XRT72L13 M13
device.
Setting this bit-field to â1â enables all âReceive DS3
Framerâ related interrupts (within the XRT72L13 M13
device) at the âBlock Levelâ.
NOTE: Setting this bit-field to â1â does not enable all
âReceive DS3 Framerâ related interrupts. Each of these
interrupts can still be disabled at the âSourceâ Level. How-
ever, setting this bit-field to â0â does disable all âReceive
DS3 Framerâ related interrupt.
Bit 4 - M13 Interrupt Enable
This âRead/Writeâ bit-field permits the user to enable-
or disable all âM13 Multiplexerâ related interrupts
(within the XRT72L13) at the âBlock Level.
Setting this bit-field to â0â disables all âM13 Multiplex-
erâ related interrupts within the XRT72L13 M13 de-
vice.
Setting this bit-field to â1â disables all âM13 Multiplex-
erâ related interrupts (within the XRT72L13 M13 de-
vice) at the âBlock Levelâ.
Bit 1 - Tx DS3 Interrupt Enable
This âRead/Writeâ bit-field permits the user to enable
or disable the âTransmit DS3 Framerâ related inter-
rupts (within the XRT72L13) at the Block Level.
Setting this bit-field to â0â disables all âTransmit DS3
Framerâ related interrupts within the XRT72L13 M13
device.
Setting this bit-field to â1â disables all âTransmit DS3
Framerâ related interrupts (within the XRT72L13 M13
device) at the âBlock Levelâ.
Bit 0 - One Second Interrupt Enable
This âRead/Writeâ bit-field permits the user to enable
or disable the âOne Secondâ Interrupt, within the
XRT72L13. If this interrupt is enabled then the
XRT72L13 will generate interrupts to the Micropro-
cessor/Microcontroller at âone-secondâ intervals.
Setting this bit-field to â0â disables the âOne Secondâ
interrupt. Conversely, setting this bit-field to â1â en-
ables the âOne Secondâ interrupt.
2.3.2.7 Block Interrupt Status Register
BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X05)
BIT 7
Rx DS3
Interrupt
Status
R/O
0
BIT 6
Not Used
BIT 5
Not Used
R/O
R/O
0
0
BIT 4
M13
Interrupt
Status
R/O
0
BIT 3
Not Used
BIT 2
Not Used
R/O
R/O
0
0
BIT 1
Tx DS3
Interrupt
Status
R/O
0
BIT 0
One
Second
Interrupt
Status
RUR
0
Bit 7 - Rx DS3 Interrupt Status
This âRead-Onlyâ bit-field indicates whether or not a
âReceive DS3 Framerâ related Interrupt has been re-
quested and is awaiting service.
If this bit-field is set to â0â, then there are no âReceive
DS3 Framerâ related interrupts awaiting service.
Conversely, if this bit-field is set to â1â, then there is at
least one âReceive DS3 Framerâ related interrupt,
awaiting service.
Bit 4 - M13 Multiplexer Interrupt Status
86
|
▷ |