XRT72L13 Datasheet, PDF (316/370 Pages) Exar Corporation – M13 MULTIPLEXER/CLEAR CHANNEL DS3 FRAMER IC
XRT72L13
M13 MULTIPLEXER/CLEAR CHANNEL DS3 FRAMER IC
REV. P1.0.6
áç
PRELIMINARY
The Receive DS3 HDLC Controller block can be used
to receive either "bit-oriented signaling" (BOS) or
"message-oriented signaling" (MOS) type data link
messages. The Receive DS3 HDLC Controller block
can also be configured to receive both types of mes-
sage from the remote terminal equipment.
Both "BOS" and "MOS" types of HDLC message pro-
cessing are discussed in detail below.
4.3.3.1 Bit-Oriented Signaling (or FEAC) Pro-
cessing via the Receive DS3 HDLC Controller.
The "Receive DS3 HDLC Controller" block consists of
two major "sub-blocks"
• The "Receive FEAC" Processor
• The "LAPD Receiver"
This section describes how to operate the "Receive
FEAC Processor".
If the "Receive DS3 Framer" block is operating in the
"C-bit Parity" Framing format, then the FEAC bit-field
within the DS3 Frame can be used to receive FEAC
(Far End Alarm and Control) messages (See
Figure 103 ). Each FEAC code word is actually six
bits in length. However, this six bit FEAC Code word
is encapsulated with 10 framing bits to form a 16 bit
message of the form:
FEAC CODE WORD
FRAMING
0 d5 d4 d3 d2 d1 d0 0
1
1
1
1
1
1
1
1
Where, "[d5, d4, d3, d2, d1, d0]" is the FEAC Code
word. The rightmost bit of the 16-bit data structure
(e.g., a "1") will be received first. Since each DS3
Frame contains only 1 FEAC bit-field, 16 DS3 Frames
are required to transmit the 16 bit FEAC code mes-
sage. The six bits, labeled "d5” through “d0”" can
represent 64 distinct messages, of which 43 have
been defined in the standards.
The Receive FEAC Processor frames and "validates"
the incoming FEAC data from the "remote" Transmit
FEAC Processor via the received FEAC channel. Ad-
ditionally, the Receive FEAC Processor will write the
"Received FEAC code words" into an 8 bit "Rx-FEAC"
register. Framing is performed by looking for two "0s"
spaced 6 bits apart preceded by 8 "1s". The Receive
DS3 HDLC Controller contains two registers that sup-
port FEAC Message Reception.
• Rx DS3 FEAC Register (Address = 0x16)
• Rx DS3 FEAC Interrupt Enable/Status Register
(Address = 0x17)
The Receive FEAC Processor generates an interrupt
upon "validation" and "removal" of the incoming
FEAC Code words.
Operation of the Receive DS3 FEAC Processor
The Receive FEAC Processor will "validate" or "re-
move" FEAC code words; that it receives from the "re-
mote" Transmit FEAC Processor. The "FEAC Code
Validation" and "Removal" functions are described
below.
FEAC Code Validation
When the remote terminal equipment wishes to send
a FEAC message to the "Local" Receive FEAC Pro-
cessor, it (the remote terminal equipment) will trans-
mit this 16 bit message, repeatedly for a total of 10
times. The Receive FEAC Processor will frame to
this incoming FEAC Code Message, and will attempt
to "validate" this message. Once the Receive FEAC
Processor has received the same FEAC code word in
at least 8 out of the last 10 received codes, it will "val-
idate" this code word by writing this 6 bit code word
into the “Receive DS3 FEAC” Register. The Receive
FEAC Processor will then inform the µC/µP of this
"Receive FEAC validation" event by generating a "Rx
FEAC Valid" interrupt and asserting the "FEAC Valid"
and the Rx FEAC Valid Interrupt Status Bits in the Rx
DS3 Interrupt Enable/Status Register, as depicted
below. The Bit Format of the Rx DS3 FEAC Register
is presented below.
RX DS3 FEAC INTERRUPT ENABLE/STATUS REGISTER (ADDRESS = 0X17)
BIT 7
Not Used
BIT 6
Not Used
BIT 5
Not Used
BIT 4
FEAC
Valid
RO
RO
RO
RO
X
X
X
1
BIT 3
RxFEAC
Remove
Interrupt
Enable
R/W
X
BIT2
RxFEAC
Remove
Interrupt
status
RUR
0
BIT 1
RxFEAC
Valid
Interrupt
Enable
R/W
1
BIT 0
RxFEAC
Valid
Interrupt
Status
RUR
1
304