2.3.2.89 LCV One Second Accumulator Regis-
ter - LSB
LCV - ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X6F)
áç
PRELIMINARY
BIT 7
RO
0
BIT 6
RO
0
BIT 5
BIT 4
BIT 3
BIT 2
LCV - One Second Count - Low Byte
RO
RO
RO
RO
0
0
0
0
BIT 1
RO
0
BIT 0
RO
0
This "Read-Only" register, along with the "LCV - One
Second Accumulator Register - MSB" (Address =
0x6E) contains a 16-bit representation of the number
of "LCV (Line Code Violation) Events that have been
detected by the Receive DS3 Framer block, within the
last one second sampling period. This register con-
tains the LSB (or Lower-Byte) value of this 16 bit ex-
pression.
2.3.2.90 P-Bit Error One Second Accumulator
Register - MSB
P-BIT ERRORS - ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X70)
BIT 7
RO
0
BIT 6
RO
0
BIT 5
BIT 4
BIT 3
BIT 2
Frame Parity Error Count - High Byte
RO
RO
RO
RO
0
0
0
0
BIT 1
RO
0
BIT 0
RO
0
This "Read-Only" register, along with the "Frame Par-
ity Errors - One Second Accumulator Register - LSB"
(Address = 0x71) contains a 16-bit representation of
the number of "P-bit” Errors that have been detected
by the Receive DS3 Framer block, within the last one
second sampling period. This register contains the
MSB (or Upper-Byte) value of this 16 bit expression.
2.3.2.91 P-Bit Error One Second Accumulator
Register - LSB
P-BIT ERRORS - ONE SECOND ACCUMULATOR REGISTER - LSB (ADDRESS = 0X71)
BIT 7
RO
0
BIT 6
RO
0
BIT 5
BIT 4
BIT 3
BIT 2
Frame Parity Error Count - Low Byte
RO
RO
RO
RO
0
0
0
0
BIT 1
RO
0
BIT 0
RO
0
This "Read-Only" register, along with the "Frame Par-
ity Errors - One Second Accumulator Register - MSB"
(Address = 0x70) contains a 16-bit representation of
the number of "P-bit” Errors that have been detected
by the Receive DS3 Framer block, within the last one-
second sampling period. This register contains the
LSB (or Lower-Byte) value of this 16 bit expression.
2.3.2.92 CP-Bit Error One Second Accumulator
Register - MSB
CP-BIT ERRORS - ONE SECOND ACCUMULATOR REGISTER - MSB (ADDRESS = 0X72)
BIT 7
RO
0
BIT 6
RO
0
BIT 5
RO
0
BIT 4
BIT 3
CP Bit Error Count - High Byte
RO
RO
0
0
BIT 2
RO
0
BIT 1
RO
0
BIT 0
RO
0
This “Read-Only” register, along with the “Frame CP-
Bit Error - One Second Accumulator Register - LSB”
(Address = 0x73) contains a 16-bit representation of
the number of “CP Bit Errors” tjhat have been detect-
ed by the Receive DS3 Framer block, within the last
one-second sampling period. This register contains
the MSB (or Upper Byte) value of this 16-bit expres-
sion.
140