20.4.3. Data Register
The SMBus Data register SMB0DAT holds a byte of serial data to be transmitted or one that has just been
received. Software may safely read or write to the data register when the SI flag is set. Software should not
attempt to access the SMB0DAT register when the SMBus is enabled and the SI flag is cleared to logic 0,
as the interface may be in the process of shifting a byte of data into or out of the register.
Data in SMB0DAT is always shifted out MSB first. After a byte has been received, the first bit of received
data is located at the MSB of SMB0DAT. While data is being shifted out, data on the bus is simultaneously
being shifted in. SMB0DAT always contains the last data byte present on the bus. In the event of lost arbi-
tration, the transition from master transmitter to slave receiver is made with the correct data or address in
SMB0DAT.
SFR Definition 20.3. SMB0DAT: SMBus Data
Bit
7
6
5
4
3
2
1
0
Name
SMB0DAT[7:0]
Type
R/W
Reset
0
0
0
0
0
0
0
0
SFR Address = 0xC2; SMB0DAT = 0x00
Bit
Name
Function
7:0 SMB0DAT[7:0] SMBus Data.
The SMB0DAT register contains a byte of data to be transmitted on the SMBus
serial interface or a byte that has just been received on the SMBus serial interface.
The CPU can read from or write to this register whenever the SI serial interrupt flag
(SMB0CN.0) is set to logic 1. The serial data in the register remains stable as long
as the SI flag is set. When the SI flag is not set, the system may be in the process
of shifting data in/out and the CPU should not attempt to access this register.
20.5. SMBus Transfer Modes
The SMBus interface may be configured to operate as master and/or slave. At any particular time, it will be
operating in one of the following four modes: Master Transmitter, Master Receiver, Slave Transmitter, or
Slave Receiver. The SMBus interface enters Master Mode any time a START is generated, and remains in
Master Mode until it loses an arbitration or generates a STOP. An SMBus interrupt is generated at the end
of all SMBus byte frames. As a receiver, the interrupt for an ACK occurs before the ACK. As a transmitter,
interrupts occur after the ACK.
Rev. 1.1
197