C8051F54X_14 Datasheet, PDF (175/275 Pages) Silicon Laboratories – Mixed Signal ISP Flash MCU Family
C8051F54x
1. Check the DONE bit (LIN0ST.0) and the ERROR bit (LIN0ST.2).
2. If performing a master receive operation and the transfer was successful, read the received data from
the data buffer.
3. If the transfer was not successful, check the error register to determine the kind of error. Further error
handling has to be done by the application.
4. Set the RSTINT (LIN0CTRL.3) and RSTERR bits (LIN0CTRL.2) to reset the interrupt request and the
error flags.
19.4. LIN Slave Mode Operation
When the device is configured for slave mode operation, it must wait for a command from a master node.
Access from the firmware to the data buffer and ID registers of the LIN controller is only possible when a
data request is pending (DTREQ bit (LIN0ST.4) is 1) and also when the LIN bus is not active (ACTIVE bit
(LIN0ST.7) is set to 0).
The LIN controller in slave mode detects the header of the message frame sent by the LIN master. If slave
synchronization is enabled (autobaud), the slave synchronizes its internal bit time to the master bit time.
The LIN controller configured for slave mode will generated an interrupt in one of three situations:
1. After the reception of the IDENTIFIER FIELD
2. When an error is detected
3. When the message transfer is completed.
The application should perform the following steps when an interrupt is detected:
1. Check the status of the DTREQ bit (LIN0ST.4). This bit is set when the IDENTIFIER FIELD has been
received.
2. If DTREQ (LIN0ST.4) is set, read the identifier from LIN0ID and process it. If DTREQ (LIN0ST.4) is not
set, continue to step 7.
3. Set the TXRX bit (LIN0CTRL.5) to 1 if the current frame is a transmit operation for the slave and set to
0 if the current frame is a receive operation for the slave.
4. Load the data length into LIN0SIZE.
5. For a slave transmit operation, load the data to transmit into the data buffer.
6. Set the DTACK bit (LIN0CTRL.4). Continue to step 10.
7. If DTREQ (LIN0ST.4) is not set, check the DONE bit (LIN0ST.0). The transmission was successful if the
DONE bit is set.
8. If the transmission was successful and the current frame was a receive operation for the slave, load the
received data bytes from the data buffer.
9. If the transmission was not successful, check LIN0ERR to determine the nature of the error. Further
error handling has to be done by the application.
10.Set the RSTINT (LIN0CTRL.3) and RSTERR bits (LIN0CTRL.2) to reset the interrupt request and the
error flags.
In addition to these steps, the application should be aware of the following:
1. If the current frame is a transmit operation for the slave, steps 1 through 5 must be completed during
the IN-FRAME RESPONSE SPACE. If it is not completed in time, a timeout will be detected by the
master.
2. If the current frame is a receive operation for the slave, steps 1 through 5 have to be finished until the
reception of the first byte after the IDENTIFIER FIELD. Otherwise, the internal receive buffer of the LIN
controller will be overwritten and a timeout error will be detected in the LIN controller.