English
Language : 

TLK3134_1 Datasheet, PDF (120/150 Pages) Texas Instruments – 4-Channel Multi-Rate Transceiver
TLK3134
4-Channel Multi-Rate Transceiver
SLLS838D – MAY 2007 – REVISED JULY 2008
4.11 HSTL Output Switching Characteristics (DDR Timing Mode Only)
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
tsetup RXDATA setup prior to RXCLK
transition high or low
Source Centered, See Figure 4-5.
Note: Cload = 10 pF, using timing reference of
VDDQ/2
thold RXDATA hold after RXCLK transition Source Centered, See Figure 4-5.
high or low
Note: Cload = 10 pF, using timing reference of
VDDQ/2
Tduty RXCLK Duty Cycle
Source Centered and Source Aligned.
Note: Cload = 10 pF, using timing reference of
VDDQ/2.
tperiod
Tfreq
Tpd
RXCLK Period
RXCLK Frequency
RXCLK rising or falling to RXDATA
valid.
Source Centered and Source Aligned
Source Centered and Source Aligned
Source Aligned, See Figure 4-6.
Note: Cload = 10 pF, using timing reference of
VDDQ/2
(1) In TBID/NBID Modes Only, the maximum allowed RXCLK period is 33.33 ns.
(2) In TBID/NBID Modes Only, the minimum allowed RXCLK frequency is 30 MHz.
MIN
0.15 ×
tperiod
NOM
0.15 ×
tperiod
45%
6.25
60 (2)
–0.10 ×
tperiod
www.ti.com
MAX UNIT
ps
ps
55%
16.67 (1)
160
+0.10 ×
tperiod
ns
MHz
ps
RXCLK
tPERIOD
VOH(ac)
VDDQ/2
VOL(ac)
tSETUP
tHOLD
tSETUP
tHOLD
VOH(ac)
RXDATA VDDQ/2
VOL(ac)
Figure 4-5. HSTL (DDR Timing Mode Only) Source Centered Output Timing Requirements
RXCLK
VOH(ac)
RXDATA VDDQ/2
VOL(ac)
Tpd
Tpd
VOH(ac)
VDDQ/2
VOL(ac)
Figure 4-6. HSTL (DDR Timing Mode Only) Source Aligned Output Timing Requirements
120 Electrical Specifications
Submit Documentation Feedback