English
Language : 

TLK3134_1 Datasheet, PDF (108/150 Pages) Texas Instruments – 4-Channel Multi-Rate Transceiver
TLK3134
4-Channel Multi-Rate Transceiver
SLLS838D – MAY 2007 – REVISED JULY 2008
www.ti.com
SIGNAL
TDP3/TDN3
TDP2/TDN2
TDP1/TDN1
TDP0/TDN0
RDP3/RDN3
RDP2/RDN2
RDP1/RDN1
RDP0/RDN0
LOCATION
U8
U7
R6
R7
U5
U4
R3
R4
U13
U14
R13
R12
U10
U11
R10
R9
Table 3-5. Serial Side Data/Clock Pins
VOLTAGE
TYPE
DESCRIPTION
AVDD
Transmit Differential Pairs, XAUI Lane, High speed serial outputs. The
CML Output data rate of these signals is from 600 Mbps minimum to 3.75 Gbps
maximum.
AVDD
CML Input
Receive Differential Pairs, XAUI Lane, High speed serial inputs with
on-chip 100 ohm differential termination. Each input pair is terminated
differentially across an on chip 100 ohm resistor. The data rate of
these signals is from 600 Mbps minimum to 3.75 Gbps maximum.
SIGNAL
VPP
TESTEN
AMUX1
AMUX0
RES[4:1]
GPI1
GPO[4:0]
LOCATION
D11
E11
M6
T12
T6
C14
H15
G2
C4
R2
J6
K6
L6
L3
N1
VOLTAGE
DVDD
VDDO
VDDA
VDDA
VDDQ
VDDO
VDDO
Table 3-6. Miscellaneous Pins
TYPE
P
LVCMOS 2.5 V
Input
Analog Output
Analog Output
Resistive
Connection
LVCMOS 2.5 V
Input
LVCMOS 2.5 V
Output
DESCRIPTION
Efuse Controller Voltage (1.2 V). Must be tied to 1.2 V (DVDD) in the
system application.
Test Mode Enable Input – Must Be Grounded in the System
Application.
SERDES Analog Mux 1 RX – Must be Unconnected/Open in the
System Application
SERDES Analog Mux 0 TX – Must be Unconnected/Open in the
System Application
HSTL Impedance Control Resistors – 0.5% Tolerance Resistor
required of the following values:
150 Ohms between RES4 and GND
150 Ohms between RES3 and GND
50 Ohms between RES2 and GND
50 Ohms between RES1 and GND
Note: These resistors cannot be shared between output pins.
General Purpose Input – Must be Grounded in the System
Application.
General Purpose Outputs – Must be Unconnected/Open in the
System Application.
It is recommended that these output ports go to headers or
non-populated resistor pads to facilitate probing of internal device
functions/settings during the initial system bring up process.
Also, to monitor PRBS testing real time, these outputs must be
available for probing on the application board.
108 Device Reset Requirements/Procedure
Submit Documentation Feedback