English
Language : 

MC68HC908GT16 Datasheet, PDF (264/412 Pages) Motorola, Inc – Microcontrollers
Enhanced Serial Communications Interface (ESCI)
To verify the start bit and to detect noise, data recovery logic takes
samples at RT3, RT5, and RT7. Table 18-2 summarizes the results of
the start bit verification samples.
Table 18-2. Start Bit Verification
RT3, RT5, and RT7 Samples
000
001
010
011
100
101
110
111
Start Bit Verification
Yes
Yes
Yes
No
Yes
No
No
No
Noise Flag
0
1
1
0
1
0
0
0
If start bit verification is not successful, the RT clock is reset and a new
search for a start bit begins.
To determine the value of a data bit and to detect noise, recovery logic
takes samples at RT8, RT9, and RT10. Table 18-3 summarizes the
results of the data bit samples.
Table 18-3. Data Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Data Bit Determination
0
0
0
1
0
1
1
1
Noise Flag
0
1
1
1
1
1
1
0
NOTE:
The RT8, RT9, and RT10 samples do not affect start bit verification. If
any or all of the RT8, RT9, and RT10 start bit samples are logic 1s
following a successful start bit verification, the noise flag (NF) is set and
the receiver assumes that the bit is a start bit.
Technical Data
264
MC68HC908GT16 • MC68HC908GT8 — Rev. 2
Enhanced Serial Communications Interface (ESCI) Module
MOTOROLA