English
Language : 

MC68HC908GT16 Datasheet, PDF (106/412 Pages) Motorola, Inc – Microcontrollers
Break Module (BRK)
BRKA — Break Active Bit
This read/write status and control bit is set when a break address
match occurs. Writing a logic 1 to BRKA generates a break interrupt.
Clear BRKA by writing a logic 0 to it before exiting the break routine.
Reset clears the BRKA bit.
1 = (When read) Break address match
0 = (When read) No break address match
6.6.2 Break Address Registers
The break address registers (BRKH and BRKL) contain the high and low
bytes of the desired breakpoint address. Reset clears the break address
registers.
Address: $FE09
Bit 7
6
5
4
3
2
1
Bit 0
Read:
Bit 15
14
13
12
11
10
Write:
9
Bit 8
Reset: 0
0
0
0
0
0
0
0
Figure 6-4. Break Address Register High (BRKH)
Address: $FE0A
Bit 7
6
5
4
3
2
1
Bit 0
Read:
Bit 7
6
5
4
3
2
1
Bit 0
Write:
Reset: 0
0
0
0
0
0
0
0
Figure 6-5. Break Address Register Low (BRKL)
Technical Data
106
MC68HC908GT16 • MC68HC908GT8 — Rev. 2
Break Module (BRK)
MOTOROLA