MC68HC908AS32A Datasheet, PDF (94/280 Pages) Freescale Semiconductor, Inc – Microcontrollers
Byte Data Link Controller (BDLC)
4.6.5 BDLC Data Register
Address: $003F
Bit 7
6
5
4
3
2
1
Bit 0
Read:
D7
D6
D5
D4
D3
D2
D1
D0
Write:
Reset:
Unaffected by Reset
Figure 4-21. BDLC Data Register (BDR)
This register is used to pass the data to be transmitted to the J1850 bus from the CPU to the BDLC. It is
also used to pass data received from the J1850 bus to the CPU. Each data byte (after the first one) should
be written only after a Tx data register empty (TDRE) state is indicated in the BSVR.
Data read from this register will be the last data byte received from the J1850 bus. This received data
should only be read after an Rx data register full (RDRF) interrupt has occurred. See 4.6.4 BDLC State
Vector Register.
The BDR is double buffered via a transmit shadow register and a receive shadow register. After the byte
in the transmit shift register has been transmitted, the byte currently stored in the transmit shadow register
is loaded into the transmit shift register. Once the transmit shift register has shifted the first bit out, the
TDRE flag is set, and the shadow register is ready to accept the next data byte. The receive shadow
register works similarly. Once a complete byte has been received, the receive shift register stores the
newly received byte into the receive shadow register. The RDRF flag is set to indicate that a new byte of
data has been received. The programmer has one BDLC byte reception time to read the shadow register
and clear the RDRF flag before the shadow register is overwritten by the newly received byte.
To abort an in-progress transmission, the programmer should stop loading data into the BDR. This will
cause a transmitter underrun error and the BDLC automatically will disable the transmitter on the next
non-byte boundary. This means that the earliest a transmission can be halted is after at least one byte
plus two extra logic 1s have been transmitted. The receiver will pick this up as an error and relay it in the
state vector register as an invalid symbol error.
NOTE
The extra logic 1s are an enhancement to the J1850 protocol which forces
a byte boundary condition fault. This is helpful in preventing noise from
going onto the J1850 bus from a corrupted message.
4.7 Low-Power Modes
The following information concerns wait mode and stop mode.
4.7.1 Wait Mode
This power-conserving mode is entered automatically from run mode whenever the CPU executes a
WAIT instruction and the WCM bit in BDLC control register 1 (BCR1) is previously clear. In BDLC wait
mode, the BDLC cannot drive any data.
A subsequent successfully received message, including one that is in progress at the time that this mode
is entered, will cause the BDLC to wake up and generate a CPU interrupt request if the interrupt enable
(IE) bit in the BDLC control register 1 (BCR1) is previously set. (See 4.6.2 BDLC Control Register 1 for a
MC68HC908AS32A Data Sheet, Rev. 2.0
94
Freescale Semiconductor