Problem Fix/Workaround
Check the Channel Counter Register before writing the update register.
40.24.2.2 PWM: Update when PWM_CPRDx = 0
When Channel Period Register equals 0, the period update is not operational.
Problem Fix/Workaround
Do not write 0 in the period register.
40.24.2.3 PWM: Counter Start Value
In left aligned mode, the first start value of the counter is 0. For the other periods, the counter starts at 1.
Problem Fix/Workaround
None.
40.24.2.4 PWM: Constraints on Duty Cycle Value
Setting Channel Duty Cycle Register (PWM_CDTYx) at 0 in center aligned mode or at 0 or 1 in left aligned mode
may change the polarity of the signal.
Problem Fix/Workaround
Do not set PWM_CDTYx at 0 in center aligned mode.
Do not set PWM_CDTYx at 0 or 1 in left aligned mode.
40.24.2.5 PWM: Behavior of CHIDx Status Bits in the PWM_SR Register
Erratic behavior of the CHIDx status bit in the PWM_SR Register. When a channel is disabled by writing in the
PWM_DIS Register just after enabling it (before completion of a Clock Period of the clock selected for the channel),
the PWM line is internally disabled but the CHIDx status bit in the PWM_SR stays at 1.
Problem Fix/Workaround
Do not disable a channel before completion of one period of the selected clock.
40.24.3 Real Time Timer (RTT)
40.24.3.1 RTT: Possible Event Loss when Reading RTT_SR
If an event (RTTINC or ALMS) occurs within the same slow clock cycle during which the RTT_SR is read, the cor-
responding bit might be cleared. This can lead to the loss of this event.
Problem Fix/Workaround:
The software must handle the RTT event as an interrupt and should not poll RTT_SR.
40.24.4 Serial Peripheral Interface (SPI)
40.24.4.1 SPI: Bad Serial Clock Generation on 2nd Chip Select
Bad Serial clock generation on the 2nd chip select when SCBR = 1, CPOL = 1 and NCPHA = 0.
This occurs using SPI with the following conditions:
• Master Mode
• CPOL = 1 and NCPHA = 0
• Multiple chip selects are used with one transfer with Baud rate (SCBR) equal to 1 (i.e., when serial clock
frequency equals the system clock frequency) and the other transfers set with SCBR are not equal to 1
• Transmitting with the slowest chip select and then with the fastest one, then an additional pulse is generated
on output SPCK during the second transfer.