SAM7S256_14 Datasheet, PDF (347/775 Pages) ATMEL Corporation – ARM-based Flash MCU | |||
|
◁ |
Note: Switching from Master to Slave mode is only permitted when TXCOMP = 1.
⢠SVDIS: TWI Slave Mode Disabled
0 = No effect.
1 = The slave mode is disabled. The shifter and holding characters (if it contains data) are transmitted in case of read oper-
ation. In write operation, the character being transferred must be completely received before disabling.
⢠SWRST: Software Reset
0 = No effect.
1 = Equivalent to a system reset.
SAM7S Series [DATASHEET]
6175MâATARMâ26-Oct-12
347
|
▷ |