40.11.7 Pulse Width Modulation Controller (PWM)
40.11.7.1 PWM: Update when PWM_CCNTx = 0 or 1
If the Channel Counter Register value is 0 or 1, the Channel Period Register or Channel Duty Cycle Register is
directly modified when writing the Channel Update Register.
Problem Fix/Workaround
Check the Channel Counter Register before writing the update register.
40.11.7.2 PWM: Update when PWM_CPRDx = 0
When Channel Period Register equals 0, the period update is not operational.
Problem Fix/Workaround
Do not write 0 in the period register.
40.11.7.3 PWM: Counter Start Value
In left aligned mode, the first start value of the counter is 0. For the other periods, the counter starts at 1.
Problem Fix/Workaround
None.
40.11.7.4 PWM: Constraints on Duty Cycle Value
Setting Channel Duty Cycle Register (PWM_CDTYx) at 0 in center aligned mode or at 0 or 1 in left aligned mode
may change the polarity of the signal.
Problem Fix/Workaround
Do not set PWM_CDTYx at 0 in center aligned mode.
Do not set PWM_CDTYx at 0 or 1 in left aligned mode.
40.11.7.5 PWM: Behavior of CHIDx Status Bits in the PWM_SR Register
Erratic behavior of the CHIDx status bit in the PWM_SR Register. When a channel is disabled by writing in the
PWM_DIS Register just after enabling it (before completion of a Clock Period of the clock selected for the channel),
the PWM line is internally disabled but the CHIDx status bit in the PWM_SR stays at 1.
Problem Fix/Workaround
Do not disable a channel before completion of one period of the selected clock.
40.11.8 Real Time Timer (RTT)
40.11.8.1 RTT: Possible Event Loss when Reading RTT_SR
If an event (RTTINC or ALMS) occurs within the same slow clock cycle during which the RTT_SR is read, the cor-
responding bit might be cleared. This can lead to the loss of this event.
Problem Fix/Workaround:
The software must handle the RTT event as an interrupt and should not poll RTT_SR.
40.11.8.2 RTT: RTT_VR May be Corrupted
Under certain rare circumstances, the Real-time Timer Value (RTT_VR) may be corrupted.
Problem Fix/Workaround
Use RTTINC as an increment for a software counter.