Refer to Chapter 8 of the Universal Serial Bus Specification, Rev. 2.0 for more information on DATA0, DATA1 packet
definitions.
• EPEDS: Endpoint Enable Disable
Read:
0 = Endpoint disabled.
1 = Endpoint enabled.
Write:
0 = Disables endpoint.
1 = Enables endpoint.
Control endpoints are always enabled. Reading or writing this field has no effect on control endpoints.
Note: After reset, all endpoints are configured as control endpoints (zero).
• RXBYTECNT[10:0]: Number of Bytes Available in the FIFO
Read-only
When the host sends a data packet to the device, the USB device stores the data in the FIFO and notifies the microcon-
troller. The microcontroller can load the data from the FIFO by reading RXBYTECENT bytes in the UDP_ FDRx register.