35.6.9 UDP Reset Endpoint Register
Register Name:
UDP_ RST_EP
Access Type:
Read-write
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
EP3
EP2
EP1
EP0
• EP0: Reset Endpoint 0
• EP1: Reset Endpoint 1
• EP2: Reset Endpoint 2
• EP3: Reset Endpoint 3
This flag is used to reset the FIFO associated with the endpoint and the bit RXBYTECOUNT in the register UDP_CSRx.It
also resets the data toggle to DATA0. It is useful after removing a HALT condition on a BULK endpoint. Refer to Chapter
5.8.5 in the USB Serial Bus Specification, Rev.2.0.
Warning: This flag must be cleared at the end of the reset. It does not clear UDP_ CSRx flags.
0 = No reset.
1 = Forces the corresponding endpoint FIF0 pointers to 0, therefore RXBYTECNT field is read at 0 in UDP_ CSRx register.
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12