These figures represent the power consumption typically measured on the power supplies..
Table 37-7. Power Consumption for Different Modes
Mode
Conditions
Consumption Unit
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
Active, running out of Flash, 8 MHz ARM Core clock is 8 MHz.
(SAM7S64/321/32/161/16)
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
7.6
mA
4.4
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated
Active, running out of Flash, 8 MHz ARM Core clock is 8 MHz.
(SAM7S512/256/128)
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
8.4
mA
8.2
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
Active, running out of Flash, 16 MHz ARM Core clock is 16 MHz.
(SAM7S64/321/32/161/16)
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
12.3
mA
12.1
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
Active, running out of Flash, 16 MHz ARM Core clock is 16 MHz.
(SAM7S512/256/128)
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
13.5
mA
13.3
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
562