English
Language : 

SAM7S256_14 Datasheet, PDF (337/775 Pages) ATMEL Corporation – ARM-based Flash MCU
30.9 Slave Mode
30.9.1 Definition
The Slave Mode is defined as a mode where the device receives the clock and the address from another device
called the master.
In this mode, the device never initiates and never completes the transmission (START, REPEATED_START and
STOP conditions are always provided by the master).
30.9.2 Application Block Diagram
Figure 30-23. Slave Mode Typical Application Block Diagram
VDD
Master
Host with
TWI
Interface
TWD
TWCK
R
R
Host with TWI
Interface
Slave 1
Host with TWI
Interface
Slave 2
LCD Controller
Slave 3
30.9.3 Programming Slave Mode
The following fields must be programmed before entering Slave mode:
1. SADR (TWI_SMR): The slave device address is used in order to be accessed by master devices in read
or write mode.
2. MSDIS (TWI_CR): Disable the master mode.
3. SVEN (TWI_CR): Enable the slave mode.
As the device receives the clock, values written in TWI_CWGR are not taken into account.
30.9.4 Receiving Data
After a Start or Repeated Start condition is detected and if the address sent by the Master matches with the Slave
address programmed in the SADR (Slave ADdress) field, SVACC (Slave ACCess) flag is set and SVREAD (Slave
READ) indicates the direction of the transfer.
SVACC remains high until a STOP condition or a repeated START is detected. When such a condition is detected,
EOSACC (End Of Slave ACCess) flag is set.
30.9.4.1 Read Sequence
In the case of a Read sequence (SVREAD is high), TWI transfers data written in the TWI_THR (TWI Transmit
Holding Register) until a STOP condition or a REPEATED_START + an address different from SADR is detected.
Note that at the end of the read sequence TXCOMP (Transmission Complete) flag is set and SVACC reset.
As soon as data is written in the TWI_THR, TXRDY (Transmit Holding Register Ready) flag is reset, and it is set
when the shift register is empty and the sent data acknowledged or not. If the data is not acknowledged, the NACK
flag is set.
Note that a STOP or a repeated START always follows a NACK.
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
337