M16C26A Datasheet, PDF (210/352 Pages) Renesas Technology Corp – 16-BIT SINGLE-CHIP MICROCOMPUTER M16C FAMILY / M16C/Tiny SERIES
M16C/26A Group (M16C/26A, M16C/26B, M16C/26T)
14. A/D Converter
A/D control register 0 (1)
b7 b6 b5 b4 b3 b2 b1 b0
11
Symbol
ADCON0
Address
03D616
Bit symbol
Bit name
CH0
Analog Input Pin
Select Bit
CH1
After reset
00000XXX 2
Function
Invalid in repeat sweep mode 0
CH2
MD0
MD1
TRG
A/D Operation Mode
Select Bit 0
Trigger Select Bit
b4 b3
1 1 : Repeat sweep mode 0 or
Repeat sweep mode 1
0 : Software trigger
1 : Hardware trigger (AD TRG trigger)
ADST
A/D Conversion Start
Flag
0 : A/D conversion disabled
1 : A/D conversion started
CKS0
Frequency Select Bit 0
Refer to Table 14.2 A/D Conversion
Frequency Select
NOTE:
1. If the ADCON0 register is rewritten during A/D conversion, the conversion result will be indeterminate.
RW
RW
RW
RW
RW
RW
RW
RW
RW
A/D control register 1 (1)
b7 b6 b5 b4 b3 b2 b1 b0
1
0
Symbol
ADCON1
Address
03D716
After reset
0016
Bit symbol
Bit name
Function
RW
A/D Sweep Pin
When selecting repeat sweep mode 0
RW
SCAN0 Select Bit (2)
b1 b0
0 0 : AN0 to AN1 (2 pins)
0 1 : AN0 to AN3 (4 pins)
SCAN1
1 0 : AN0 to AN5 (6 pins)
1 1 : AN0 to AN7 (8 pins)
RW
MD2
A/D Operation Mode
Select Bit 1
0 : Any mode other than repeat sweep
mode 1
RW
BITS
8/10-Bit Mode Select Bit 0 : 8-bit mode
1 : 10-bit mode
RW
CKS1
Frequency Select Bit 1 Refer to Table 14.2 A/D Conversion
RW
Frequency Select
VCUT
VREF Connect Bit (3)
1 : VREF connected
RW
(b7-b6)
Nothing is assigned. When write, set to “0”.
When read, its content is “0”.
NOTES:
1. If the ADCON1 register is rewritten during A/D conversion, the conversion result will be indeterminate.
2. AN30 to AN32 can be used in the same way as AN0 to AN7. Use the ADGSEL1 to ADGSET0 bits in the ADCON2
register to select the desired pin.
3. If the VCUT bit is reset from “0” (VREF unconnected) to “1” (VREF connected), wait for 1 µs or more before starting A/D
conversion.
A/D control register 2 (1)
b7 b6 b5 b4 b3 b2 b1 b0
00
Symbol
ADCON2
Address
03D416
After reset
0016
Bit symbol
Bit name
SMP
A/D Conversion Method
Select Bit
ADGSEL0 A/D Input Group
Select Bit
ADGSEL1
(b3)
CKS2
Reserved Bit
Frequency Select Bit 2
Function
0 : Without sample and hold
1 : With sample and hold
b2 b1
0 0 : Select port P10 group (AN i)
0 1 : Select port P9 group (AN 3i)
1 0 : Do not set
1 1 : Do not set
Set to “0”
Refer to Table 14.2 A/D Conversion
Frequency Select
RW
RW
RW
RW
RW
RW
TRG1
Trigger Select Bit 1
Set to "0" in repeat sweep mode 0
RW
(b7-b6)
Nothing is assigned. When write, set to “0”.
When read, its content is “0”.
NOTE:
1. If the ADCON2 register is rewritten during A/D conversion, the conversion result will be indeterminate.
Figure 14.1.4.2 ADCON0 to ADCON2 Registers in Repeat Sweep Mode 0
Rev. 2.00 Feb.15, 2007 page 193 of 329
REJ09B0202-0200