N25Q032A13E1241F Datasheet, PDF (69/153 Pages) Micron Technology – 32-Mbit 3 V, multiple I/O, 4-Kbyte subsector erase, XiP enabled, serial flash memory with 108 MHz SPI bus interface
N25Q032 - 3 V
Instructions
Figure 23. Dual Input Extended Fast Program instruction sequence
S
Mode 3
C Mode 0
DQ0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Instruction
24-bit Address
22 20 18 16 14 12 10 8 6 4 2 0
DQ1
23 21 19 17 15 13 11 9 7 5 3 1
S
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38
C
DQ0
DQ1
9.1.15
642064206420 6420
Data In 1
Data In 2
Data In 3
Data In 4
7531753175317531
MSB
MSB
MSB
MSB
6420
Data In 256
7531
MSB
*Address bits A23 and A22 are “Don’t Care.”
Quad Input Fast Program
The Quad Input Fast Program (QIFP) instruction is very similar to the Dual Input Fast
Program (DIFP) instruction, except that the data are entered on four pins (pin DQ0, pin
DQ1, pin W/VPP/DQ2 and pin HOLD/ (DQ3) instead of only two. Inputting the data on four
pins instead of two doubles the data transfer bandwidth compared to the Dual Input Fast
Program (DIFP) instruction.
The Quad Input Fast Program (QIFP) instruction is entered by driving Chip Select (S) Low,
followed by the instruction code, three address bytes on Serial Data input (DQ0), and at
least one data byte on Serial Data I/Os (DQ0, DQ1, DQ2, DQ3).
If the 8 least significant address bits (A7-A0) are not all zero, all transmitted data that go
beyond the end of the current page are programmed from the start address of the same
page (from the address whose 8 least significant bits (A7-A0) are all zero). Chip Select (S)
must be driven Low for the entire duration of the sequence.
If more than 256 bytes are sent to the device, previously latched data are discarded and the
last 256 data bytes are guaranteed to be programmed correctly within the same page. If less
than 256 data bytes are sent to device, they are correctly programmed at the requested
addresses without having any effects on the other bytes in the same page.
For optimized timings, it is recommended to use the Quad Input Fast Program (QIFP)
instruction to program all consecutive targeted bytes in a single sequence rather to using
69/153
Micron Technology, Inc., reserves the right to change products or specifications without notice.
©2010 Micron Technology, Inc. All rights reserved.