Section 16 Serial Communication Interface 3 (SCI3)
Start transmission
[1] Read SSR and check that the TDRE flag is
set to 1, then write transmit data to TDR.
[1]
Read TDRE flag in SSR
When data is written to TDR, the TDRE flag
is automatically cleared to 0 and clocks are
output to start the data transmission.
TDRE = 1
No
[2] To continue serial transmission, be sure to
read 1 from the TDRE flag to confirm that
writing is possible, then write data to TDR.
Yes
When data is written to TDR, the TDRE flag
is automatically cleared to 0.
Write transmit data to TDR
Yes
[2]
All data transmitted?
No
Read TEND flag in SSR
No
TEND = 1
Yes
Clear TE bit in SCR3 to 0
<End>
Figure 16.11 Sample Serial Transmission Flowchart (Clock Synchronous Mode)
Rev. 3.00 Sep. 10, 2007 Page 313 of 528