Section 13 Timer Z
13.3.6 Timer Output Control Register (TOCR)
TOCR selects the initial outputs before the first occurrence of a compare match. Note that bits
OLS1 and OLS0 in TFCR set these initial outputs in reset synchronous PWM mode and
complementary PWM mode.
Initial
Bit
Bit Name Value R/W Description
7
TOD1
0
R/W Output Level Select D1
0: 0 output at the FTIOD1 pin*
1: 1 output at the FTIOD1 pin*
6
TOC1
0
R/W Output Level Select C1
0: 0 output at the FTIOC1 pin*
1: 1 output at the FTIOC1 pin*
5
TOB1
0
R/W Output Level Select B1
0: 0 output at the FTIOB1 pin*
1: 1 output at the FTIOB1 pin*
4
TOA1
0
R/W Output Level Select A1
0: 0 output at the FTIOA1 pin*
1: 1 output at the FTIOA1 pin*
3
TOD0
0
R/W Output Level Select D0
0: 0 output at the FTIOD0 pin*
1: 1 output at the FTIOD0 pin*
2
TOC0
0
R/W Output Level Select C0
0: 0 output at the FTIOC0 pin*
1: 1 output at the FTIOC0 pin*
1
TOB0
0
R/W Output Level Select B0
0: 0 output at the FTIOB0 pin*
1: 1 output at the FTIOB0 pin*
0
TOA0
0
R/W Output Level Select A0
0: 0 output at the FTIOA0 pin*
1: 1 output at the FTIOA0 pin*
Note: * The change of the setting is immediately reflected in the output value.