Section 16 Serial Communication Interface 3 (SCI3)
Table 16.6 shows the states of the SSR status flags and receive data handling when a receive error
is detected. If a receive error is detected, the RDRF flag retains its state before receiving data.
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 16.8 shows a sample flow chart
for serial data reception.
Table 16.6 SSR Status Flags and Receive Data Handling
SSR Status Flag
RDRF* OER
FER
PER
Receive Data
Receive Error Type
1
1
0
0
Lost
Overrun error
0
0
1
0
Transferred to RDR Framing error
0
0
0
1
Transferred to RDR Parity error
1
1
1
0
Lost
Overrun error + framing error
1
1
0
1
Lost
Overrun error + parity error
0
0
1
1
Transferred to RDR Framing error + parity error
1
1
1
1
Lost
Overrun error + framing error +
parity error
Note: * The RDRF flag retains the state it had before data reception.