AMD-K6™-2E Processor Data Sheet
Table 53. Typical and Maximum Power Dissipation for OPN Suffix AFR (Standard-Power Devices)
Clock Control State 233 MHz1 266 MHz1 300 MHz1,3 333 MHz1,2 350 MHz3 400 MHz1,3
Thermal Power
(Maximum)4,5
13.50 W
14.70 W
17.20 W
19.00 W
19.95 W
16.90 W
Thermal Power
(Typical)6
8.10
8.85 W
10.35 W
11.40 W
11.98 W
10.15 W
Stop Grant/Halt
(Maximum)7
2.46 W
2.48 W
2.50 W
3.94 W
3.96 W
4.40 W
Stop Clock
(Maximum)8
2.25 W
2.25
2.25 W
3.50 W
3.50 W
4.00 W
Notes:
1. This specification applies to components using a CLK frequency of 66 MHz.
2. This specification applies to components using a CLK frequency of 95 MHz.
3. This specification applies to components using a CLK frequency of 100 MHz.
4. The maximum power dissipated in the normal clock control state must be taken into account when designing a solution for
thermal dissipation for the AMD-K6-2E processor.
5. Maximum power is determined for the worst-case instruction sequence or function for the listed clock control states with
VCC2 = 2.2 V, and VCC3 = 3.3 V.
6. Typical power is determined for the typical instruction sequences or functions associated with normal system operation with
VCC2 = 2.2 V, and VCC3 = 3.3 V.
7. The CLK signal and the internal PLL are still running but most internal clocking has stopped.
8. The CLK signal, the internal PLL, and all internal clocking has stopped.
Chapter 14
Electrical Data
259