English
Language : 

HD6433937 Datasheet, PDF (366/521 Pages) Hitachi Semiconductor – Hardware Manual
s: Setting Number. Receiver control setting for which this packet’s values are to be applied. The
following truth table shows the names of each of the values for s that apply to this packet.
s3 s2 s1 s0
01 11
10 00
10 01
Setting Name
1600sps Sync
3200sps Data
1600sps Data
LBC: Low Battery Check. If this bit is set, the FLEX decoder will check the status of the LOBAT
port just before leaving this receiver state. (value after reset=0)
CLS: Control Line Setting. This is the value to be output on the receiver control lines (S0-S7) for
this receiver state. (value after reset=0)
5. Receiver Shut Down Setting Packets
Table 12-15 Receiver Shut Down Setting Packet Bit Assignments
Byte 3
Byte 2
Byte 1
Byte 0
Bit 7
0
SE
CLS 7
0
Bit 6
0
0
CLS 6
0
Bit 5
0
0
CLS 5
ST 5
Bit 4
1
0
CLS 4
ST 4
Bit 3
1
LBC
CLS 3
ST 3
Bit 2
0
0
CLS 2
ST 2
Bit 1
1
0
CLS 1
ST 1
Bit 0
s
0
CLS0
ST 0
s: Setting Number. Receiver control setting for which this packet’s values are to be applied. The
following truth table shows the names of each of the values for s that apply to this packet.
s
Setting Name
0
Shut Down 1
1
Shut Down 2
SE: Step Enable. The receiver setting is enabled when the bit is set. If a step in the shut down
sequence is disabled, all steps following the disabled step will be ignored. (value after reset=0)
LBC: Low Battery Check. If this bit is set, the FLEX decoder will check the status of the LOBAT
port just before leaving this receiver state. (value after reset=0)
CLS: Control Line Setting. This is the value to be output on the receiver control lines (S0-S7) for
this receiver state. (value after reset=0)
354