English
Language : 

80KSBR200 Datasheet, PDF (96/172 Pages) Integrated Device Technology – sRIO SERIAL BUFFER FLOW-CONTROL DEVICE
IDT 80KSBR200
Notes
Advanced Datasheet*
The current value for the ADDRESS. Whenever a new case scenario is programmed, this value will be set to be iden-
tical to the START ADDRESS. The address will increment by the quantity of data transmitted with every packet. The NEXT
ADDRESS will not rise beyond the STOP ADDRESS. If the Wrap or Stop bit in the following register is set to WRAP, the
NEXT address will reset to the START ADDRESS whenever STOP ADDRESS has been hit. If the wrap occurs in the
middle of the packet, the NEXT ADDRESS will increment after the reset to indicate how much of the tail of the packet was
written after the wrap.
Name: CS0_NEXT_ADDR
Address: 0x18408
Bit
30:0
Field Name
NEXT_ADDR
31
-
Type
Reset
Value
Comment
RW
31h0
Next Address:
Current memory address for sRIO
0
Reserved
Table 66 Case Scenario Next Address Register
Case Scenario Stop Address Register
The final incremental address for writing. The higher address may be included in the sRIO packet header, but in some
cases the packet length may cause a write to an address higher than this value, in case of an overflow. The START
ADDRESS and STOP ADDRESS should be identical if the user does not want the address issued in the packet header to
increment.
Name: CS0_STOP_ADDR
Address: 0x1840C
Bit
30:0
Field Name
STOP_ADDR
31
-
Type
Reset
Value
Comment
RW
31h0
Stop Address:
Maximum memory address for sRIO
0
Reserved
Table 67 Case Scenario Stop Address Register
Case Scenario Frame Register
Name: CS0_FRAME_REG
Address: 0x18410
Bit
9:0
14:10
15
23:16
27:24
28
Field Name
Type
Reset
Value
Comment
FRAME_SIZE
RW
10h0
Frame size
FRAME_OFFSET RW
5h0
TALLY_FLAG
RW
1b0
FRAME_COUNT RW
8h0
Frame Offset:
Offset on first count
Set Tally Flag:
1 = Send doorbell to Dest ID on count = size
Frame Count:
Counts frame, reset on doorbell
-
0
MEM_WRAP_STP RW
1b0
Reserved
Memory Wrap or Stop:
Stop or Wrap on STOP Address
Table 68 Case Scenario Frame Register
96 of 172
March 19, 2007
„2005 Integrated Device Technology, Inc. All rights reserved. Advanced Datasheet for informational purposes only. Product specifications subject to change without notice.NOT AN OFFER FOR SALE The information presented herein is subject to a
Non-Disclosure Agreement (NDA) and is for planning purposes only. Nothing contained in this presentation, whether verbal or written, is intended as, or shall have the effect of, a sale or an offer for sale that creates a contractual power of acceptance.